A
D
D
E
N I
D T
U E
M M DESCRIPTION
Addendum 1
Page 5
SHEET A600 Interior Elevations (Full Sheet Reissued)
1.45 Lowered roof structure and reduced height of the FSC1 on all elevations to coordinate building sections.
SHEET A601 Interior Elevations (Full Sheet Reissued)
1.46 On 03 Kitchen „A‟ @ Hood, revised stainless hoods to reflect Proximity Hoods that are to be installed.
SHEET A701.1 Bar Elevations (Full Sheet Reissued)
1.47 On 01 Front Bar Back Elevation, lowered Faux Taps.
SHEET A702 Enlarged Bar Plan & Elevations (Full Sheet Reissued)
1.48 On 01 Side Bar Elevation, added notes to indicate location of FRP1 and FRP2 on Plan and Elevation D.
SHEET A703 Enlarged Bar Plan & Details (Full Sheet Reissued)
1.49 On 05 Drain Pan Section, changed Bar Rail material note from SS2 to SS1.
1.50 On 02 Drain Pan Section and 06 Bar Section, added material note SS1 to countertop and bar rail.
CHANGES TO KITCHEN and EQUIPMENT DRAWINGS
SHEET EQ1 Equipment Floor Plan (Full Sheet Reissued For Reference Only)
1.51 Revised the orientation of the mechanical room and grease recovery tank.
SHEET EQ2 Equipment Schedule (Full Sheet Reissued For Reference Only)
1.52 Revised print quality of schedules to be more readable.
K3 Food Service Plumbing Plan (Full Sheet Reissued For Reference Only)
1.53 Revised 109 Bar Glasswasher in Plumbing Water Schedule.
K3 Food Service Electrical Plan (Full Sheet Reissued For Reference Only)
1.54 Revised 109 Bar Glasswasher in Electrical Schedule.
CHANGES TO MECHANICAL DRAWINGS
SHEET MEP001 MEP Site Plan (Full Sheet Reissued)
1.55 Original issue.
SHEET MEP100 Roof Plan (Full Sheet Reissued)
1.56 Moved the produce cooler and ice machine condensing unit away from the fryer exhaust fan.
1.57 Corrected gas use for the branch serving the cook line.
1.58 Added signage circuitry and connections.
1.59 Revised for use of proximity hood per request by Owner.
Comentarios a estos manuales